Evaluation of the Effectiveness of Intraoperative Ultrasonography in the Identification of Intra-Articular Screws and Long Screws

Main Article Content

Manuel Agnelo dos Santos Junior

Abstract

Surgery with plates and screws is commonly indicated for unstable distal radius fractures, and accurate assessment of screw length and positioning is essential. Conventional intraoperative fluoroscopy and radiography may fail to identify excessively long or intra-articular screws. This study evaluated the effectiveness of intraoperative ultrasonography in detecting screw positioning abnormalities during distal radius fixation. A prospective clinical study included 12 patients with distal radius fractures or malunions who underwent osteosynthesis or corrective osteotomy with plates and screws at a Brazilian hand surgery referral center. After fixation, multiple fluoroscopic views were obtained, followed by intraoperative ultrasonography. Screws were replaced when necessary. Postoperative radiography and computed tomography were subsequently performed, and the findings were statistically analyzed. Participants had a mean age of 50.03 ± 17.6 years (range: 23–76 years), and all injuries were trauma-related. The interval between trauma and surgery ranged from 14 to 23 days. A strong correlation between ultrasonography and fluoroscopic findings was observed in 86% of the evaluated cases (r = 0.854). Postoperative radiography and computed tomography showed no need for additional screw replacement. One patient (8.33%) required surgical revision because of inadequate fracture reduction. Intraoperative ultrasonography proved to be a reliable, accessible, noninvasive, and radiation-free method for evaluating screw length and positioning during distal radius fixation. However, further studies with larger samples and more rigorous methodological designs are required to confirm these findings.

Downloads

Download data is not yet available.

Article Details

Section

Original Research

How to Cite

Manuel Agnelo dos Santos Junior. (2026). Evaluation of the Effectiveness of Intraoperative Ultrasonography in the Identification of Intra-Articular Screws and Long Screws. Brazilian Journal of Health Aromatherapy and Essential Oil, 3(1), 68. https://doi.org/10.62435/2965-7253.bjhae.2026

References

1. Braga Júnior MB, Chagas Neto FA, Porto MA, Barroso TA, Lima ACM, Silva SM, et al. Epidemiologia e grau de satisfação do paciente vítima de trauma musculoesquelético atendido em hospital de emergência da rede pública brasileira. Acta Ortop Bras. 2005;13(3):137-40. DOI: https://doi.org/10.1590/S1413-78522005000300007

2. Chung KC, Shauver MJ, Yin H, Kim HM, Baser O, Birkmeyer JD. Variations in the use of internal fixation for distal radial fracture in the United States Medicare population. J Bone Joint Surg Am. 2011;93(23):2154-62. DOI: https://doi.org/10.2106/JBJS.J.012802

3. Court-Brown CM, Caesar B. Epidemiology of adult fractures: a review. Injury. 2006;37(8):691-7. DOI: https://doi.org/10.1016/j.injury.2006.04.130

4. Trease C, McIff T, Toby EB. Locking versus nonlocking T-plates for dorsally comminuted distal radius fractures: a biomechan-ical study. J Hand Surg Am. 2005;30(4):756-63. DOI: https://doi.org/10.1016/j.jhsa.2005.04.017

5. Orbay JL, Touhami A. Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res. 2006;(445):58-67. DOI: https://doi.org/10.1097/01.blo.0000205891.96575.0f

6. Thielke KH, Wagner T, Bartsch S, Echtermeyer V. Angularly stable radius plate: progress in treatment of problematic distal radius fracture? Chirurg. 2003;74(11):1057-63. DOI: https://doi.org/10.1007/s00104-003-0718-3

7. Jirangkul P, Jitprapaikulsarn S, Songpatanaslip T. Outcomes following temporary Kapandji pinning technique and distal radial LCP fixation for intra-articular fractures of the displaced distal radius. Tech Hand Up Extrem Surg. 2019;23(1):38-43. DOI: https://doi.org/10.1097/BTH.0000000000000221

8. Li J, Ma Z, Gao F, Ji Y. The measurement of dorsal radial tilt by X-ray and computed tomography. Rev Assoc Med Bras (1992). 2018;64(11):1007-11. DOI: https://doi.org/10.1590/1806-9282.64.11.1007

9. Kwon BC, Lee JK, Lee SY, Hwang JY, Seo JH. Morphometric variations in the volar aspect of the distal radius. Clin Orthop Surg. 2018;10(4):462-7. DOI: https://doi.org/10.4055/cios.2018.10.4.462

10. Neuhaus V, Badri O, Ferree S, Bot AGJ, Ring DC, Mudgal CS. Radiographic alignment of unstable distal radius fractures fixed with 1 or 2 rows of screws in volar locking plates. J Hand Surg Am. 2013;38(2):297-301. DOI: https://doi.org/10.1016/j.jhsa.2012.10.040

11. Brunner A, Siebert C, Stieger C, Kastius A, Link BC, Babst R. The dorsal tangential X-ray view to determine dorsal screw pene-tration during volar plating of distal radius fractures. J Hand Surg Am. 2015;40(1):27-33. DOI: https://doi.org/10.1016/j.jhsa.2014.10.021

12. Pichler W, Windisch G, Schaffler G, Rienmüller R, Grechenig W. Computer tomography-aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. J Hand Surg Eur Vol. 2009;34(5):598-602. DOI: https://doi.org/10.1177/1753193409101471

13. Sugun TS, Karabay N, Gurbuz Y, Ozaksar K, Toros T, Kayalar M. Screw prominences related to palmar locking plating of distal radius. J Hand Surg Eur Vol. 2011;36(4):320-4. DOI: https://doi.org/10.1177/1753193410392869

14. Riddick AP, Hickey B, White SP. Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixation. J Hand Surg Eur Vol. 2012;37(5):407-11. DOI: https://doi.org/10.1177/1753193411426809

15. Gurbuz Y, Kucuk L, Gunay H, Ozaksar K, Sugun TS, Bilge O. Comparison of ultrasound and dorsal horizon radiographic view for the detection of dorsal screw penetration. Acta Orthop Traumatol Turc. 2017;51(6):448-50. DOI: https://doi.org/10.1016/j.aott.2017.10.004

16. Vernet P, Durry A, Nicolau X, D'Ambrosio A, Collinet A, Botero Salazar S, et al. Detection of penetration of the dorsal cortex by epiphyseal screws of distal radius volar plates: anatomical study comparing ultrasound and fluoroscopy. Orthop Traumatol Surg Res. 2017;103(6):911-3. DOI: https://doi.org/10.1016/j.otsr.2017.04.001

17. Ozer K, Toker S. Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating. Hand (N Y). 2011;6(2):190-3. DOI: https://doi.org/10.1007/s11552-010-9316-2

18. Ozer K, Wolf JM, Watkins B, Hak DJ. Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius. J Hand Surg Am. 2012;37(5):963-7. DOI: https://doi.org/10.1016/j.jhsa.2012.02.026

19. Balfour GW. Using ultrasound to prevent screw penetration. J Hand Surg Am. 2016;41(3):453-6. DOI: https://doi.org/10.1016/j.jhsa.2015.12.020

20. De Maeseneer M, Marcelis S, Osteaux M, Jager T, Machiels F, Van Roy P. Sonography of a rupture of the tendon of the extensor pollicis longus muscle: initial clinical experience and correlation with findings at cadaveric dissection. AJR Am J Roentgenol. 2005;184(1):175-9. DOI: https://doi.org/10.2214/ajr.184.1.01840175

21. Santiago FR, Plazas PG, Fernández JM. Sonography findings in tears of the extensor pollicis longus tendon and correlation with CT, MRI and surgical findings. Eur J Radiol. 2008;66(1):112-6. DOI: https://doi.org/10.1016/j.ejrad.2007.05.007

22. Bianchi S, van Aaken J, Glauser T, Martinoli C, Beaulieu JY, Della Santa D. Screw impingement on the extensor tendons in distal radius fractures treated by volar plating: sonographic appearance. AJR Am J Roentgenol. 2008;191(5):W199-203. DOI: https://doi.org/10.2214/AJR.08.1057

23. Bergsma M, Brown K, Doornberg J, Sierevelt I, Jaarsma R, Jadav B. Distal radius volar plate design and volar prominence to the watershed line in clinical practice: comparison of Soong grading of 2 common plates in 400 patients. J Hand Surg Am. 2019;44(10):853-9. DOI: https://doi.org/10.1016/j.jhsa.2019.04.012